Aluminium extrusion · diagnosis without history
6 hours of downtime for a severed sensor cable, 12 minutes to know where to look
On an aluminium extrusion line, the machine goes into fault. Four hours of diagnosis later, the cause appears: a scorching piece of metal that landed in the wrong place.
About this case
A real breakdown, experienced and recounted by the site, then replayed with Mimorian with no imported history. Site anonymised.
The situation: a scorching offcut, in the wrong place
The line turns a billet into a long aluminium bar. At the line exit, a cut separates an offcut from the bar. The metal is still extremely hot.
That day, the offcut lands on a sensor and severs its cable. The machine goes into fault and stops.
The blocker: a cause that came from outside
The fault message refers to a sensor, not to a burnt cable. The technician looks inside the machine, where breakdowns usually are. The cause is a physical accident, outside the normal operation of the line.
According to the team leader who followed the whole incident: six hours of downtime, at least four of them spent searching.
The walkthrough: the same breakdown, replayed with Mimorian
The breakdown is replayed with Mimorian from the team leader's account, with no past intervention loaded in the tool.
The symptom described in everyday language
The fault and its context are described as you would tell a colleague. Mimorian asks its questions, and the exchange moves forward like a workshop discussion.
The component to check, pointed out
Within 12 minutes of conversation, Mimorian points to the element to verify and the way forward: check the sensor and its integrity, then the integrity of its cable.
The cause within reach
With that list in hand, the technician goes straight to the sensor. The burnt cable is visible at first glance.
The result: four hours of searching reduced to one targeted check
On this breakdown, the gap comes down to two figures: at least four hours of diagnosis with the machine stopped, against twelve minutes of conversation to know where to look.
Mimorian is useful from day one, before any history exists. It starts from how the machine works and from its components, and brings the search back to the right place, even when the cause comes from outside the machine.
The cause was a scorching aluminium offcut that fell on a cable. Four hours to find it, twelve minutes to know where to look.
Frequently asked questions
Can Mimorian help with no breakdown history?
Yes. In this case, no past intervention was in the tool. Mimorian starts from how the machine works and from its components to propose a diagnostic approach: which element to check, and in what order. History, when it exists, strengthens that approach.
What happens when the breakdown comes from outside the machine?
It is the typical case where time is lost: you look for an internal malfunction when the cause is a physical accident. By indicating which components to check and having their integrity verified, wiring included, Mimorian points the technician back to what can be verified straight away.
How long does it take to get a lead with Mimorian?
On this breakdown, 12 minutes of conversation were enough to point to the sensor and its cable. The time depends on the breakdown and on what is known about the machine. The conversation is held in everyday language, with no form to fill in.
Did a breakdown cost you hours of searching?
Tell us about it. We replay it with Mimorian on your machine, and you see where the diagnostic approach would have led you.
Explore the other use cases
Industrial SME · key machine
The machine idle for 18 months
No usable documentation, only paper diagrams. Modelled from scratch on site, the machine restarted the same day.
See the use caseHeavy truck manufacturer · assembly line
The fuse diagnosed in 10 minutes
A test in real conditions on an assembly line. Client's written report: 3 parts saved, 1.5 hours of repair avoided.
See the use caseFoundry and machining company · criticality upstream
The part the FMEA never saw
8 hours of downtime for a part never rated critical. Mimorian flags these components upstream, from the documentation.
See the use caseVacuum heat treatment · plant memory
The breakdown that returns every 2 years
Cycle complete, door locked, already experienced 2 years earlier. A diagnostic demonstration on the real machine, imported.
See the use casePlastics processing · machine history
The answer was sitting in the history
More than half a day of downtime the first time. With Mimorian, the cause comes out of the history in 2 minutes, backed by the wiring diagram.
See the use caseHigh-volume production · recurring breakdowns
The breakdown everyone knew about
Known unofficially, never quantified. As soon as the history is imported, two components stand out: 22 and 8 occurrences.
See the use casePrecision machining · breakdown with no alarm
The coolant flow stopped with no alarm
A silent screen, a day of diagnosis. Starting from the functional chain, Mimorian points to the filtration system and proposes a test plan: 30 minutes at most.
See the use casePharmaceutical packaging · diagnosis and improvement
The cap detected twice
Every bottle rejected. Mimorian confirms a double detection, steers the diagnosis towards the product, then prepares the improvement in 5 minutes instead of an hour.
See the use caseFood & beverage · preventive maintenance
Preventive maintenance with no wiring diagram
No diagram, an empty twin. By the end of the intervention, the machine has its digital twin and the client its report, in the format it expects.
See the use caseSpeciality chemicals · process unit
The filling that would not happen
More than two months of spaced-out interventions. Picked up again with Mimorian from the P&IDs, the search starts from how the unit works and the cause comes out in 45 minutes.
See the use case